When “ Err 01(Main Motor err!) ” appears on OP Screen.
Cause
:
This error is caused when the Main Motor does not work.
Type : SPS/A(B)-1306, SPS/A(B)-1811, SPS/A(B)-2516, SPS/A(B)-5030
Solution : Execute the Main Motor Test (Operate the machine in the following order.).
Press the MODE button in the B area.
“ Main Menu ” is displayed in the A area.
Press the button 2 in the C area.
.
“ Test Menu ” is displayed in the A area.
Press the ENTER button in the C area.
Make sure that the cursor indicates " 4.Machine Test " in the A area.
Press the button 2 in the C area.
Make sure the curser indicates “ 2.MainMotor Test ” in the A area.
Press the ENTER button in the C area.
You can control the speed of the Main Motor by pressing the SPEED button in the D area up and down.
When pressing the ENTER button in the C area, the Main Motor operates.
“ PEDAL NEUTRAL ” is displayed in the A area.
Pressing the ESC button in the D area ends the test and leads to the initial display of the test.
※ If the test is not conducted in a normal way, the reason can be a problem in the Main Board, I/O Board or Main Motor. Refer to an A/S engineer for check.