18

When “ Err 19(X - Y Error !) ” appears on OP Screen.


Cause : This error is caused when the Feed Board does not operate.
Type : SPS/A(B)-1306, SPS/A(B)-1811, SPS/A(B)-2516, SPS/A(B)-5030

Solution : Execute the Step Motor Manual Operation Test (Operate the machine in the following order)



 


Press the MODE button in the B area.
 
“Main Menu” is displayed in the A area.
 
Press the button 2 in the C area.
         
“Test Menu” is displayed in the A area.
 
Press the ENTER button in the C area.
 
Make sure the cursor indicates “4.Machine Test” in the A area.
         
Press the button 2 in the C area.
 
Make sure the cursor indicates “12.XY-Jog Test” in the A area.
 
Press the ENTER button in the C area.
         
“X-Y jogging” is displayed in the A area.
 
Press the ENTER button in the C area.
 
“X-Y jogging” is displayed in the A area.
         
Press the ENTER button in the C area.
 
“X-Y jogging” is displayed in the A area.
 
You can move the FF by pressing the related Direction button in the C area (4:left, 8:up, 2:down, 6:right)
         
       
Pressing the ESC button in the D area ends the test and leads to the initial display of the test.

※ If the test is not conducted in a normal way, the reason can be a problem in the X-Y Board, I/O Board, CPU Card, Step Motor, X/Y sensor. Refer to an A/S engineer for check.