42

When the Move to Origin is not normal.


Cause : The Origin position cannot be detected due to a problem in the X,Y Sensor or Step Motor.
Type : SPS/A(B)-1306, SPS/A(B)-1811, SPS/A(B)-2516, SPS/A(B)-5030

Solution : Execute the Origin Test (Operate the machine in the following order.).



 


Press the MODE button in the B area.
 
“Main Menu” is displayed in the A area.
 
Press the button 2 in the C area.
         
“Test Menu” is displayed in the A area.
 
Press the ENTER button in the C area.
 
Make sure the cursor indicates “4.Machine Test” in the A area.
         
Press the button 2 in the C area.
 
Make sure the cursor indicates “14.Origin Test” in the A area.
 
Press the ENTER button in the C area.
         
       
If “Press Any Key” appears in the A area, press any button to move the Feed Board to the Origin and end the test.


※ If the test is not conducted in a normal way, the reason can be a problem in the XY Sensor, I/O Board, Power Board, XY Board, Step Motor. Refer to an A/S engineer for check.